Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	31
Date	08/12/14
Start Time	10:20:03
Diameter Midpoint
 10.9	1520.7
 11.3	2657.41
 11.8	5244.41
 12.2	6588.14
 12.6	8759.62
 13.1	14111.9
 13.6	19124.8
 14.1	23553.8
 14.6	30224.3
 15.1	41738.4
 15.7	51542.9
 16.3	66091.7
 16.8	83339.4
 17.5	101934
 18.1	123875
 18.8	146485
 19.5	178142
 20.2	206495
 20.9	234837
 21.7	271127
 22.5	317667
 23.3	360678
 24.1	397855
 25.0	452944
 25.9	500657
 26.9	556474
 27.9	611932
 28.9	663868
 30.0	717906
 31.1	778160
 32.2	839535
 33.4	891470
 34.6	940504
 35.9	967801
 37.2	1.0016e+006
 38.5	1.01127e+006
 40.0	1.01833e+006
 41.4	1.0024e+006
 42.9	999818
 44.5	978867
 46.1	954876
 47.8	911367
 49.6	876964
 51.4	827858
 53.3	784558
 55.2	723566
 57.3	653357
 59.4	577163
 61.5	505359
 63.8	430870
 66.1	360860
 68.5	293586
 71.0	234976
 73.7	185381
 76.4	143016
 79.1	108938
 82.0	80730.2
 85.1	57371.8
 88.2	40920.8
 91.4	27700.5
 94.7	18657.8
 98.2	12369.4
101.8	8213.51
105.5	5178.25
109.4	3424.17
113.4	2142.17
117.6	1427.58
121.9	963.502
126.3	611.37
131.0	609.166
135.8	414.853
140.7	270.566
145.9	340.408
151.2	349.76
156.8	262.081
162.5	210.066
168.5	172.389
174.7	175.233
181.1	204.616
187.7	147.209
194.6	161.108
201.7	106.078
209.1	132.681
216.7	112.945
224.7	105.054
232.9	90.1353
241.4	125.525
250.3	92.0501
259.5	81.9011
269.0	93.6842
278.8	64.355
289.0	103.35
299.6	96.9409
310.6	104.551
322.0	94.997
333.8	98.3839
346.0	91.8454
358.7	75.7597
371.8	75.1367
385.4	67.211
399.5	67.6923
414.2	42.6289
429.4	58.5732
445.1	41.2347
461.4	55.3534
478.3	56.5565
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1956
High Voltage	9846.35
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	39.3962
Mean(nm)	41.2185
Geo. Mean(nm)	38.7964
Mode(nm)	39.9542
Geo. Std. Dev.	1.42246
Total Concentration(#/cm)	2.5465e+007
Comment	